Issue
DYMAT 2009
Volume 1, 2009
DYMAT 2009 - 9th International Conference on the Mechanical and Physical Behaviour of Materials under Dynamic Loading
Page(s) 611 - 617
Section Experimental Techniques
DOI https://doi.org/10.1051/dymat/2009087
Published online 15 September 2009
DYMAT 2009 (2009) 611-617
DOI: 10.1051/dymat/2009087

The correction for using X-cut quartz transducers in SHPB

P. Zhao1, Y. Lin1, F. Lu1, J. Li1, R. Chen1 and G. Sun2

1  College of Science, National Univ. of Defense Technology, Changsha 410073, Hunan, China
2  Naval Aeronautical Engineering Institute, Yantai 264001, Shandong, China


Published online: 15 September 2009

Abstract
A correction method for using X-cut quartz transducers in SHPB was proposed. We analyzed the error factors from the piezoelectric equation. Using numerical simulation results, we found the major error. A simple expression was built, and a set of copper standard samples was tested for calibrating the influence coefficient. The influence coefficient was validated in Al tests. With the correction method, a kind of low density polyurethane foam was investigated by SHPB using the quartz transducer. Experimental results showed that the error correction made the X-cut quartz transducer use in SHPB more convenient and valid.



© EDP Sciences 2009